Cảm biến ZLM1-B5612E41
Thông số kỹ thuật cảm biến quang Sick ZLM1-B5612E41
đại lý sick | đại lý ZLM1-B5612E41 | sick việt nam
nhà phân phối sick | nhà phân phối ZLM1-B5612E41
Thông số kỹ thuật chung Sick sensor
| Actuator | Pneumatic, valve on board |
| Max. number of sensors |
Approx. 30 Approx. 50 |
| Logical principle of operation | Single accumulation |
| Type of Release | Single release, block (slug) release |
| Dimensions (W x H x D) | 31 mm x 93 mm x 74 mm |
| Điều chỉnh | None |
| Special applications | ZoneControl |
- When powerd from the end of the IR daisy chain.
- When powerd from center of the IR daisy chain.
Mechanics/electronics
| Supply voltage | ≥ 21.6 V DC 1) |
| Ripple | pp 2) |
| Current consumption | 60 mA 3) |
| Switching output | PNP |
| Signal voltage PNP HIGH/LOW | Approx. VS – 0.5 V / 0 V |
| Output current Imax. | ≤ 100 mA |
| Time functions | Off delay |
| Delay time | 0 s … 2 s |
| Connection type | Cable with female connector, M12, 4-pin, 1.1 m 4) |
| Connection type for daisy chain | Cable with M12 male connector, 4-pin |
| Cable material | PVC |
| Circuit protection |
A 5) C 6) D 7) |
| Protection class | III |
| Housing material | Plastic, ABS |
| Enclosure rating | IP40 |
| Ambient operating temperature | –10 °C … +55 °C |
| Ambient temperature, storage | –25 °C … +75 °C |
| Medium for valves | Compressed air or neutral gases filtered, non-lubricated or lubricated |
| Design solenoid valve | 3/2-way valve 8) |
| Mode of operation solenoid valve | Air to Brake (NO) |
| Connection type solenoid valve | Compressed air 2 x 8 mm diameter, output line 4 mm diameter |
| Coil ratings | 24 V DC 2 W |
| Air flow rate | Approx. 20 Nl/min 9) |
| Ventilation capacity | Approx. 100 Nl/min |
| Operating pressure range | 0.5 bar … 8 bar 10) |
- 1) Limit values, the device may connect only to protected extra low voltage.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load and valve deenergized.
- 4) Do not bend below 0 °C.
- 5) A = VS connections reverse-polarity protected.
- 6) C = interference suppression.
- 7) D = outputs overcurrent and short-circuit protected.
- 8) Other valve types available on request.
- 9) P – A.
- 10) In combination with cylinders with small air volume we recommend tests.
Pneumatic
| Coil ratings | 24 V DC 2 W |
| Medium for valves | Compressed air or neutral gases filtered, non-lubricated or lubricated |
| Design solenoid valve | 3/2-way valve 1) |
| Connection type solenoid valve | Compressed air 2 x 8 mm diameter, output line 4 mm diameter |
| Air flow rate | Approx. 20 Nl/min 2) |
| Ventilation capacity | Approx. 100 Nl/min |
| Operating pressure range | 0.5 bar … 8 bar 3) |
- 1) Other valve types available on request.
- 2) P – A.
- 3) In combination with cylinders with small air volume we recommend tests.
Classifications
| eCl@ss 5.0 | 27270902 |
| eCl@ss 5.1.4 | 27270902 |
| eCl@ss 6.0 | 27270902 |
| eCl@ss 6.2 | 27270902 |
| eCl@ss 7.0 | 27270902 |
| eCl@ss 8.0 | 27270902 |
| eCl@ss 8.1 | 27270902 |
| eCl@ss 9.0 | 27270902 |
| eCl@ss 10.0 | 27270902 |
| eCl@ss 11.0 | 27270902 |
| eCl@ss 12.0 | 27270902 |
| ETIM 5.0 | EC002717 |
| ETIM 6.0 | EC002717 |
| ETIM 7.0 | EC002717 |
| ETIM 8.0 | EC002717 |
| UNSPSC 16.0901 | 39121528 |