Cảm biến WTT190L-N3531
Thông số kỹ thuật cảm biến quang Sick WTT190L-N3531
đại lý sick | đại lý WTT190L-N3531 | sick việt nam
nhà phân phối sick | nhà phân phối WTT190L-N3531
Thông số kỹ thuật chung Sick sensor
Nguyên tắc chức năng | Photoelectric proximity sensor |
Nguyên tắc chức năng detail | Background suppression, Optical time-of-flight |
Dimensions (W x H x D) | 17.6 mm x 46.5 mm x 34.1 mm |
Housing design (light emission) | Rectangular |
Phạm vi cảm biến max. | 200 mm … 2,500 mm |
Phạm vi cảm biến |
200 mm … 2,500 mm
|
Loại ánh sáng | Visible red light |
Nguồn sáng | Laser 3) |
Kích thước điểm sáng (khoảng cách) | Ø 10 mm (2,500 mm) |
Độ dài sóng | 658 nm |
Laser class | 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.1 |
Điều chỉnh | Potentiometer, 4 turns (1 x) |
- Object with 6 … 90 % remission (based on standard white to DIN 5033).
- Adjustable.
- 3) Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | pp 2) |
Current consumption | 75 mA 3) |
Switching output | NPN 4) |
Number of switching outputs | 1 (Q1) 4) |
Switching mode | Light/dark switching 4) |
Switching mode selector | Selectable via light/dark selector |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 0.5 ms 5) |
Switching frequency | 1,000 Hz 6) |
Analog output | – |
Input | Sender off |
Connection type | Cable with plug M12, 5-pin, 0.3 m 7) |
Cable material | PVC |
Conductor cross section | 0.14 mm² |
Circuit protection |
A 8) B 9) C 10) |
Protection class | III |
Weight | 45 g |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Enclosure rating | IP67 |
Items supplied | BEF-W190 mounting bracket |
Ambient operating temperature | –10 °C … +50 °C |
Ambient temperature, storage | –40 °C … +70 °C |
Warm-up time | 11) |
Initialization time | |
UL File No. | NRKH2.E300503 |
- 1) Limit values. Operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load. At VS = 24 V.
- 4) Q1 = 1 switching threshold, light/dark switching selectable via light/dark selector.
- 5) Signal transit time with resistive load.
- 6) With light/dark ratio 1:1.
- 7) Do not bend below 0 °C.
- 8) A = VS connections reverse-polarity protected.
- 9) B = inputs and output reverse-polarity protected.
- 10) C = interference suppression.
- 11) For optimum performance observe max. warm-up time of 5 minutes.
Safety-related parameters
MTTFD | 216 years |
DCavg | 0 % |
Classifications
eCl@ss 5.0 | 27270904 |
eCl@ss 5.1.4 | 27270904 |
eCl@ss 6.0 | 27270904 |
eCl@ss 6.2 | 27270904 |
eCl@ss 7.0 | 27270904 |
eCl@ss 8.0 | 27270904 |
eCl@ss 8.1 | 27270904 |
eCl@ss 9.0 | 27270904 |
eCl@ss 10.0 | 27270904 |
eCl@ss 11.0 | 27270904 |
eCl@ss 12.0 | 27270903 |
ETIM 5.0 | EC002719 |
ETIM 6.0 | EC002719 |
ETIM 7.0 | EC002719 |
ETIM 8.0 | EC002719 |
UNSPSC 16.0901 | 39121528 |