Thông số kỹ thuật cảm biến quang Sick WTT12L-B2543
đại lý sick | đại lý WTT12L-B2543 | sick việt nam
nhà phân phối sick | nhà phân phối WTT12L-B2543
Thông số kỹ thuật chung Sick sensor
Nguyên tắc chức năng | Photoelectric proximity sensor |
Nguyên tắc chức năng detail | Background suppression, Optical time-of-flight |
Dimensions (W x H x D) | 20 mm x 49.6 mm x 44.2 mm |
Housing design (light emission) | Rectangular |
Phạm vi cảm biến max. | 50 mm … 1,800 mm |
Phạm vi cảm biến |
100 mm … 1,800 mm 3) |
Loại ánh sáng | Visible red light |
Nguồn sáng | Laser 4) |
Kích thước điểm sáng (khoảng cách) | Ø 12 mm (1,800 mm) |
Độ dài sóng | 658 nm |
Laser class | 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.1 |
Điều chỉnh | Single teach-in button (2 x) |
- Object with 6 … 90 % remission (based on standard white to DIN 5033).
- Adjustable.
- 3) Object with 90% remission (based on standard white, DIN 5033).
- 4) Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | pp 2) |
Current consumption | 70 mA 3) |
Switching output | Push-pull: PNP/NPN 4) |
Number of switching outputs | 2 (Q1, Q2) 4) |
Switching mode | Light switching 4) |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 16.7 ms 5) |
Switching frequency | 30 Hz 6) |
Analog output | – |
Input | Sender off |
Connection type | Male connector M12, 5-pin |
Circuit protection |
A 7) B 8) C 9) |
Protection class | III |
Weight | 48 g |
Housing material | Plastic, VISTAL® |
Optics material | Plastic, PMMA |
Enclosure rating | IP67 |
Ambient operating temperature | –35 °C … +50 °C 10) |
Ambient temperature, storage | –40 °C … +70 °C |
Warm-up time | 11) |
Initialization time | |
UL File No. | NRKH.E181493 |
- 1) Limit values. Operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load. At VS = 24 V.
- 4) Q1, Q2 = 2 switching thresholds, light switching.
- 5) Signal transit time with resistive load.
- 6) With light/dark ratio 1:1.
- 7) A = VS connections reverse-polarity protected.
- 8) B = inputs and output reverse-polarity protected.
- 9) C = interference suppression.
- 10) As of Ta = 45 °C, a max.load current Imax = 50 mA is permitted.
- 11) Below Tu = –10 °C a warm-up time is necessary.
Safety-related parameters
MTTFD | 138 years |
DCavg | 0 % |
TM (mission time) | 20 years |
Classifications
eCl@ss 5.0 | 27270904 |
eCl@ss 5.1.4 | 27270904 |
eCl@ss 6.0 | 27270904 |
eCl@ss 6.2 | 27270904 |
eCl@ss 7.0 | 27270904 |
eCl@ss 8.0 | 27270904 |
eCl@ss 8.1 | 27270904 |
eCl@ss 9.0 | 27270904 |
eCl@ss 10.0 | 27270904 |
eCl@ss 11.0 | 27270904 |
eCl@ss 12.0 | 27270903 |
ETIM 5.0 | EC002719 |
ETIM 6.0 | EC002719 |
ETIM 7.0 | EC002719 |
ETIM 8.0 | EC002719 |
UNSPSC 16.0901 | 39121528 |