Cảm biến WTR1-P721S09
Thông số kỹ thuật cảm biến quang Sick WTR1-P721S09
đại lý sick | đại lý WTR1-P721S09 | sick việt nam
nhà phân phối sick | nhà phân phối WTR1-P721S09
Thông số kỹ thuật chung Sick sensor
Nguyên tắc chức năng | Photoelectric proximity sensor |
Nguyên tắc chức năng detail | Background suppression |
Actuator | Pneumatic, valve on board |
Max. number of sensors | Approx. 30 |
Logical principle of operation | Single accumulation, single release, block (slug) release |
Dimensions (W x H x D) | 51.5 mm x 151.4 mm x 46 mm |
Phạm vi cảm biến max. | 300 mm … 900 mm |
Phạm vi cảm biến | 300 mm … 900 mm |
Loại ánh sáng | Infrared light |
Nguồn sáng | LED |
Kích thước điểm sáng (khoảng cách) | Ø 40 mm (900 mm) |
Điều chỉnh | Potentiometer |
Special applications | ZoneControl |
- Maximum per individual incoming power supply at 27.6 V DC.
- Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 21.6 V DC … 27.6 V DC 1) |
Ripple | pp 2) |
Current consumption | 25 mA 3) |
Switching output | PNP |
Switching mode | Dark switching |
Signal voltage PNP HIGH/LOW | Approx. UV – |
Output current Imax. | ≤ 100 mA |
Switching frequency | 250 Hz |
Time functions | On delay |
Delay time | 0 s … 5 s |
Connection type | Male connector M12, 4-pin |
Connection type for daisy chain | Cable with female connector, M12, 4-pin, 2.5 m |
Circuit protection |
A 4) C 5) D 6) |
Protection class | II 7) |
Weight | 175 g |
Special device | ✔ |
Housing material | Plastic, ABS |
Enclosure rating | IP54 |
Shock and vibration resistance | According to IEC 68 |
Ambient operating temperature | –10 °C … +55 °C |
Ambient temperature, storage | –25 °C … +75 °C |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
Medium for valves | Compressed air or neutral gases filtered, non-lubricated or lubricated |
Design solenoid valve | 3/2-way valve 8) |
Mode of operation solenoid valve | Air to Drive (NC) |
Connection type solenoid valve | Compressed air 2 x 8 mm diameter, output line 4 mm diameter |
Coil ratings | 24 V DC 1 W |
Air flow rate | Approx. 20 Nl/min 9) |
Ventilation capacity | Approx. 130 Nl/min |
Operating pressure range | 2 bar … 8 bar 10) |
- 1) Limit values.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load and valve deenergized.
- 4) A = VS connections reverse-polarity protected.
- 5) C = interference suppression.
- 6) D = outputs overcurrent and short-circuit protected.
- 7) Reference voltage: 50 V DC.
- 8) Other valve types available on request.
- 9) P – A.
- 10) In combination with cylinders with small air volume we recommend tests.
Pneumatic
Coil ratings | 24 V DC 1 W |
Medium for valves | Compressed air or neutral gases filtered, non-lubricated or lubricated |
Design solenoid valve | 3/2-way valve 1) |
Connection type solenoid valve | Compressed air 2 x 8 mm diameter, output line 4 mm diameter |
Air flow rate | Approx. 20 Nl/min 2) |
Ventilation capacity | Approx. 130 Nl/min |
Operating pressure range | 2 bar … 8 bar 3) |
- 1) Other valve types available on request.
- 2) P – A.
- 3) In combination with cylinders with small air volume we recommend tests.
Classifications
eCl@ss 5.0 | 27270904 |
eCl@ss 5.1.4 | 27270904 |
eCl@ss 6.0 | 27270904 |
eCl@ss 6.2 | 27270904 |
eCl@ss 7.0 | 27270904 |
eCl@ss 8.0 | 27270904 |
eCl@ss 8.1 | 27270904 |
eCl@ss 9.0 | 27270904 |
eCl@ss 10.0 | 27270904 |
eCl@ss 11.0 | 27270904 |
eCl@ss 12.0 | 27270903 |
ETIM 5.0 | EC002719 |
ETIM 6.0 | EC002719 |
ETIM 7.0 | EC002719 |
ETIM 8.0 | EC002719 |
UNSPSC 16.0901 | 39121528 |