Cảm biến WSE280-2P2431
Thông số kỹ thuật cảm biến quang Sick WSE280-2P2431
đại lý sick | đại lý WSE280-2P2431 | sick việt nam
nhà phân phối sick | nhà phân phối WSE280-2P2431
Thông số kỹ thuật chung Sick sensor
Nguyên tắc chức năng | Through-beam photoelectric sensor |
Dimensions (W x H x D) | 23.5 mm x 74.5 mm x 63 mm |
Housing design (light emission) | Rectangular |
Phạm vi cảm biến max. | 0 m … 60 m |
Phạm vi cảm biến | 0 m … 50 m |
Loại ánh sáng | Visible red light |
Nguồn sáng | LED 1) |
Kích thước điểm sáng (khoảng cách) | Ø 0.6 m (20 m) |
Điều chỉnh | Potentiometer |
- 1) Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | pp 2) |
Power consumption, sender | ≤ 20 mA |
Power consumption, receiver | ≤ 20 mA 3) |
Switching output | PNP |
Switching mode | Light/dark switching |
Switching mode selector | Selectable via light/dark rotary switch |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 0.5 ms 4) |
Switching frequency | 1,000 Hz 5) |
Connection type | Male connector M12, 4-pin |
Circuit protection |
A 6) B 7) C 8) D 9) |
Protection class | III |
Weight | 300 g |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Enclosure rating |
IP66 IP67 |
Items supplied | Mounting bracket BEF-W280 |
Electromagnetic compatibility (EMC) | EN 60947-5-2 10) |
Ambient operating temperature | –25 °C … +55 °C |
Ambient temperature, storage | –40 °C … +70 °C |
UL File No. | NRKH2.E300503 & NRKH8.E300503 |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) A = VS connections reverse-polarity protected.
- 7) B = inputs and output reverse-polarity protected.
- 8) C = interference suppression.
- 9) D = outputs overcurrent and short-circuit protected.
- 10) The AC/DC devices (-2Rxxxx only) comply with the Radio Safety Requirements for the industrial sector (Radio Safety Class A). They may cause radio interference if used in a residential area.
Classifications
eCl@ss 5.0 | 27270901 |
eCl@ss 5.1.4 | 27270901 |
eCl@ss 6.0 | 27270901 |
eCl@ss 6.2 | 27270901 |
eCl@ss 7.0 | 27270901 |
eCl@ss 8.0 | 27270901 |
eCl@ss 8.1 | 27270901 |
eCl@ss 9.0 | 27270901 |
eCl@ss 10.0 | 27270901 |
eCl@ss 11.0 | 27270901 |
eCl@ss 12.0 | 27270901 |
ETIM 5.0 | EC002716 |
ETIM 6.0 | EC002716 |
ETIM 7.0 | EC002716 |
ETIM 8.0 | EC002716 |
UNSPSC 16.0901 | 39121528 |