Cảm biến WS/WE45-P260S01
Thông số kỹ thuật cảm biến quang Sick WS/WE45-P260S01
đại lý sick | đại lý WS/WE45-P260S01 | sick việt nam
nhà phân phối sick | nhà phân phối WS/WE45-P260S01
Thông số kỹ thuật chung Sick sensor
Nguyên tắc chức năng | Through-beam photoelectric sensor |
Dimensions (W x H x D) | 60 mm x 105 mm x 105 mm |
Housing design (light emission) | Rectangular |
Phạm vi cảm biến max. | 0 m … 35 m |
Phạm vi cảm biến | 0 m … 35 m |
Loại ánh sáng | Visible red light |
Nguồn sáng | LED |
Kích thước điểm sáng (khoảng cách) | Ø 560 mm (35 m) |
Điều chỉnh | Potentiometer |
Special features | For the detection of hot objects with surface temperatures of > 800 °C |
- Valid only for ambient temperature.
- Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 60 V DC 1) |
Ripple | pp 2) |
Power consumption, sender | 50 mA 3) |
Power consumption, receiver | 50 mA 3) |
Switching output | PNP |
Output function | Complementary |
Switching mode | Light/dark switching |
Output current Imax. | ≤ 200 mA |
Response time | ≤ 500 µs 4) |
Switching frequency | 1,000 Hz 5) |
Time functions |
On delay Off delay ON and OFF delay |
Delay time |
Adjustable via time delay selector switch, 0.5 s … 12 s 0.015 s … 0.3 s |
Connection type | Terminal connection with PG13,5, 6-pin |
Circuit protection |
A 6) C 7) D 8) |
Protection class | I 9) |
Weight | 1,600 g |
Alarm output | 100 mA 10) |
Special device | ✔ |
Housing material | Metal |
Enclosure rating | IP67 |
Items supplied | Cooling plate BEF-KP-W 45 and special protection hood OBS-W45-H not included in scope of delivery |
Test input sender off | TE to 0 V |
Ambient operating temperature | –25 °C … +55 °C 11) |
Ambient temperature, storage | –40 °C … +70 °C |
Part number of individual components | 2018948 WE45-P260S01 2018949 WS45-D260S01 |
- 1) Limit values.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Signal transit time with resistive load.
- 5) With light/dark ratio 1:1.
- 6) A = VS connections reverse-polarity protected.
- 7) C = interference suppression.
- 8) D = outputs overcurrent and short-circuit protected.
- 9) Reference voltage: 50 V DC.
- 10) Flashes at approx. 5 Hz, switch to VS.
- 11) Up to 120 °C with cooling plates BEF-KP-W 45.
Safety-related parameters
MTTFD | 263 years |
DCavg | 0 % |
Classifications
eCl@ss 5.0 | 27270901 |
eCl@ss 5.1.4 | 27270901 |
eCl@ss 6.0 | 27270901 |
eCl@ss 6.2 | 27270901 |
eCl@ss 7.0 | 27270901 |
eCl@ss 8.0 | 27270901 |
eCl@ss 8.1 | 27270901 |
eCl@ss 9.0 | 27270901 |
eCl@ss 10.0 | 27270901 |
eCl@ss 11.0 | 27270901 |
eCl@ss 12.0 | 27270901 |
ETIM 5.0 | EC002716 |
ETIM 6.0 | EC002716 |
ETIM 7.0 | EC002716 |
ETIM 8.0 | EC002716 |
UNSPSC 16.0901 | 39121528 |