Cảm biến WL9LGC-3P2232B02
Thông số kỹ thuật cảm biến quang Sick WL9LGC-3P2232B02
đại lý sick | đại lý WL9LGC-3P2232B02 | sick việt nam
nhà phân phối sick | nhà phân phối WL9LGC-3P2232B02
| Nguyên tắc chức năng | Photoelectric retro-reflective sensor |
| Nguyên tắc chức năng detail | Autocollimation |
| Dimensions (W x H x D) | 12.2 mm x 52.2 mm x 23.6 mm |
| Housing design (light emission) | Rectangular |
| Mounting hole | M3 |
| Phạm vi cảm biến max. |
0 m … 4.5 m
|
| Phạm vi cảm biến |
0 m … 2 m
|
| Loại ánh sáng | Visible red light |
| Nguồn sáng | Laser 3) |
| Kích thước điểm sáng (khoảng cách) | Ø 1 mm (500 mm) |
| Độ dài sóng | 650 nm |
| Laser class | 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.1 |
| Điều chỉnh |
IO-Link Single teach-in button |
| Pin 2 configuration | External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output |
| AutoAdapt | ✔ |
| Special applications | Detecting small objects, Detecting transparent objects |
| Special features | On delay, 40 ms |
- Reflective tape REF-AC1000.
- To ensure reliable operation, we recommend using REF-AC1000 reflective tape or reflective-tap reflectors such as P41F, PLV14-A, PLH25-M12, or PLH25-D12. Reflectors with large-scale triple structures must only be used if deemed suitable for the application.
- 3) Tuổi thọ trung bình: 50,000 h at TU = +25 °C.
| Supply voltage | 10 V DC … 30 V DC 1) |
| Ripple | pp 2) |
| Current consumption | 30 mA 3) |
| Switching output | PNP 4) |
| Output function | Complementary |
| Switching mode | Light/dark switching 4) |
| Output current Imax. | ≤ 100 mA |
| Response time | ≤ 0.5 ms 5) |
| Response time Q/ on Pin 2 | 300 µs … 450 µs 5)6) |
| Switching frequency | 1,000 Hz 7) |
| Switching frequency Q / to pin 2 | ≤ 1,000 Hz 8) |
| Connection type | Male connector M8, 4-pin |
| Circuit protection |
A 9) B 10) C 11) |
| Protection class | III |
| Weight | 13 g |
| Polarisation filter | ✔ |
| Housing material | Plastic, VISTAL® |
| Optics material | Plastic, PMMA |
| Enclosure rating |
IP66 IP67 IP69K |
| Special feature | Detecting transparent objects |
| Ambient operating temperature | –10 °C … +50 °C |
| Ambient operating temperature extended | –30 °C … +55 °C 12)13) |
| Ambient temperature, storage | –30 °C … +70 °C |
| UL File No. | NRKH.E181493 |
| Repeatability Q/ on Pin 2: | 150 µs 6) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Q = light switching.
- 5) Signal transit time with resistive load.
- 6) Valid for Q on Pin2, if configured with software.
- 7) With light/dark ratio 1:1.
- 8) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
- 9) A = VS connections reverse-polarity protected.
- 10) B = inputs and output reverse-polarity protected.
- 11) C = interference suppression.
- 12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
| MTTFD | 562 years (EN ISO 13849-1) 1) |
| DCavg | 0 % |
| TM (mission time) | 10 years |
- 1) Mode of calculation: Parts-Count-calculation.
| Communication interface | IO-Link V1.1 |
| Communication Interface detail | COM2 (38,4 kBaud) |
| Cycle time | 2.3 ms |
| Process data length | 16 Bit |
| Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = empty |
| VendorID | 26 |
| DeviceID HEX | 0x800116 |
| DeviceID DEC | 8388886 |
| Smart Task name | Base logics | ||||||
| Logic function |
Direct AND OR WINDOW Hysteresis |
||||||
| Timer function |
Deactivated On delay Off delay ON and OFF delay Impulse (one shot) |
||||||
| Inverter | Yes | ||||||
| Switching frequency |
SIO Direct: 1000 Hz 1) SIO Logic: 1000 Hz 2) IOL: 900 Hz 3) |
||||||
| Response time |
SIO Direct: 300 µs … 450 µs 1) SIO Logic: 500 µs … 600 µs 2) IOL: 500 µs … 900 µs 3) |
||||||
| Repeatability |
SIO Direct: 150 µs 1) SIO Logic: 150 µs 2) IOL: 400 µs 3) |
||||||
|
|||||||
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.