Cảm biến WL9LC-3P3432A00
Thông số kỹ thuật cảm biến quang Sick WL9LC-3P3432A00
đại lý sick | đại lý WL9LC-3P3432A00 | sick việt nam
nhà phân phối sick | nhà phân phối WL9LC-3P3432A00
Nguyên tắc chức năng | Photoelectric retro-reflective sensor |
Nguyên tắc chức năng detail | Autocollimation |
Dimensions (W x H x D) | 12.2 mm x 52.2 mm x 23.6 mm |
Housing design (light emission) | Rectangular |
Mounting hole | M3 |
Phạm vi cảm biến max. | 0 m … 12 m |
Phạm vi cảm biến | 0 m … 8 m |
Loại ánh sáng | Visible red light |
Nguồn sáng | Laser |
Kích thước điểm sáng (khoảng cách) | Ø 1 mm (500 mm) |
Độ dài sóng | 650 nm |
Laser class | 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.1 |
Điều chỉnh |
IO-Link Single teach-in button |
Pin 2 configuration | External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output |
Special applications | Detecting small objects |
- Reflector PL80A.
- Tuổi thọ trung bình: 50,000 h at TU = +25 °C.
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | pp 2) |
Current consumption | 30 mA 3) |
Switching output | PNP 4) |
Output function | Complementary |
Switching mode | Light/dark switching 4) |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 0.5 ms 5) |
Response time Q/ on Pin 2 | 300 µs … 450 µs 5)6) |
Switching frequency | 1,000 Hz 7) |
Switching frequency Q / to pin 2 | ≤ 1,000 Hz 8) |
Connection type | Cable with M12 male connector, 4-pin, 120 mm |
Circuit protection |
A 9) B 10) C 11) |
Protection class | III |
Weight | 13 g |
Polarisation filter | ✔ |
Housing material | Plastic, VISTAL® |
Optics material | Plastic, PMMA |
Enclosure rating |
IP66 IP67 IP69K |
Ambient operating temperature | –10 °C … +50 °C |
Ambient operating temperature extended | –30 °C … +55 °C 12)13) |
Ambient temperature, storage | –30 °C … +70 °C |
UL File No. | NRKH.E181493 |
Repeatability Q/ on Pin 2: | 150 µs 6) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Q = light switching.
- 5) Signal transit time with resistive load.
- 6) Valid for Q on Pin2, if configured with software.
- 7) With light/dark ratio 1:1.
- 8) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
- 9) A = VS connections reverse-polarity protected.
- 10) B = inputs and output reverse-polarity protected.
- 11) C = interference suppression.
- 12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
MTTFD | 562 years |
DCavg | 0 % |
TM (mission time) | 10 years |
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 … 15 = empty |
VendorID | 26 |
DeviceID HEX | 0x800110 |
DeviceID DEC | 8388880 |
Smart Task name | Base logics | ||||||
Logic function |
Direct AND OR WINDOW Hysteresis |
||||||
Timer function |
Deactivated On delay Off delay ON and OFF delay Impulse (one shot) |
||||||
Inverter | Yes | ||||||
Switching frequency |
SIO Direct: 1000 Hz 1) SIO Logic: 1000 Hz 2) IOL: 900 Hz 3) |
||||||
Response time |
SIO Direct: 300 µs … 450 µs 1) SIO Logic: 500 µs … 600 µs 2) IOL: 500 µs … 900 µs 3) |
||||||
Repeatability |
SIO Direct: 150 µs 1) SIO Logic: 150 µs 2) IOL: 400 µs 3) |
||||||
|
- 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.