Thông số kỹ thuật cảm biến quang Sick WL34-R230
đại lý sick | đại lý WL34-R230 | sick việt nam
nhà phân phối sick | nhà phân phối WL34-R230
| Nguyên tắc chức năng | Photoelectric retro-reflective sensor |
| Nguyên tắc chức năng detail | Dual lens |
| Dimensions (W x H x D) | 27 mm x 92 mm x 70 mm |
| Housing design (light emission) | Rectangular |
| Phạm vi cảm biến max. | 0.03 m … 22 m |
| Phạm vi cảm biến | 0.03 m … 22 m |
| Loại ánh sáng | Visible red light |
| Nguồn sáng | LED |
| Kích thước điểm sáng (khoảng cách) | Ø 250 mm (15 m) |
| Độ dài sóng | 660 nm |
| Điều chỉnh | Potentiometer |
- Reflector PL80A.
- Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
| Supply voltage | 20 V AC/DC … 250 V AC/DC |
| Power consumption | |
| Switching output | Relay, electrically isolated 1) |
| Output function | Change-over contacts |
| Switching mode |
Light switching 1) Dark switching |
| Switching mode selector | Selectable via light/dark selector |
| Switching current (switching voltage) |
4 A @ 250 V AC, 4 A @ 24 V DC, 0.125 A @ 250 V DC UL: 4 A @ 250 V AC, general use / 4 A @ 250 V AC, resistive (NO) / 3 A @ 250 V AC, resistive (NC) / 4 A @ 24 V DC, NO, general use / 3 A @ 24 V DC, NC, general use / R300 / B300 (NO contacts only) |
| Response time | ≤ 10 ms |
| Switching frequency | 10 Hz 2) |
| Connection type | Terminal connection with M16 gland |
| Circuit protection |
A 3) C 4) |
| Protection class | II 5) |
| Weight | 140 g |
| Polarisation filter | ✔ |
| Housing material | Plastic, ABS |
| Enclosure rating | IP67 |
| Ambient operating temperature | –40 °C … +60 °C |
| Ambient temperature, storage | –40 °C … +75 °C |
| UL File No. | NRKH.E181493 & NRKH7.E181493 |
- 1) Provide suitable spark suppression for inductive or capacitive loads.
- 2) With light/dark ratio 1:1.
- 3) A = VS connections reverse-polarity protected.
- 4) C = interference suppression.
- 5) Rated voltage: 250 V AC/DC.
| MTTFD | 478 years |
| DCavg | 0 % |
| TM (mission time) | 20 years |
| B10d | 59,123 Switching cycles 1) |
- 1) Only for devices containing electro-mechanical components. In this case, the MTTFD value of the entire device must be calculated from the given B10D value, the number of switching cycles and the given MTTFD value.
| eCl@ss 5.0 | 27270902 |
| eCl@ss 5.1.4 | 27270902 |
| eCl@ss 6.0 | 27270902 |
| eCl@ss 6.2 | 27270902 |
| eCl@ss 7.0 | 27270902 |
| eCl@ss 8.0 | 27270902 |
| eCl@ss 8.1 | 27270902 |
| eCl@ss 9.0 | 27270902 |
| eCl@ss 10.0 | 27270902 |
| eCl@ss 11.0 | 27270902 |
| eCl@ss 12.0 | 27270902 |
| ETIM 5.0 | EC002717 |
| ETIM 6.0 | EC002717 |
| ETIM 7.0 | EC002717 |
| ETIM 8.0 | EC002717 |
| UNSPSC 16.0901 | 39121528 |