Cảm biến VS/VE18-4P3140V
Thông số kỹ thuật cảm biến quang Sick VS/VE18-4P3140V
đại lý sick | đại lý VS/VE18-4P3140V | sick việt nam
nhà phân phối sick | nhà phân phối VS/VE18-4P3140V
Thông số kỹ thuật chung Sick sensor
| Nguyên tắc chức năng | Through-beam photoelectric sensor |
| Dimensions (W x H x D) | 18 mm x 18 mm x 83 mm |
| Housing design (light emission) | Cylindrical |
| Housing length | 83 mm |
| Thread diameter (housing) | M18 x 1 |
| Optical axis | Axial |
| Phạm vi cảm biến max. | 0 m … 20 m |
| Phạm vi cảm biến | 0 m … 18 m |
| Focus | 2.5° |
| Loại ánh sáng | Infrared light |
| Nguồn sáng | LED 1) |
| Kích thước điểm sáng (khoảng cách) | Ø 600 mm (15 m) |
| Angle of dispersion | 2.5° |
| Độ dài sóng | 880 nm |
| Điều chỉnh | None |
| Special applications | Hygienic and washdown zones |
- 1) Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
| Supply voltage | 10 V DC … 30 V DC 1) |
| Ripple | ± 10 % 2) |
| Power consumption, sender | 35 mA 3) |
| Power consumption, receiver | 40 mA 3) |
| Switching output | PNP 4) |
| Switching mode | Light/dark switching 4) |
| Switching mode selector | Selectable via L/D control cable |
| Signal voltage PNP HIGH/LOW | Approx. VS – 2.0 V / 0 V |
| Output current Imax. | ≤ 100 mA |
| Response time | ≤ 2 ms 5) |
| Switching frequency | 250 Hz 6) |
| Angle of reception | 8° |
| Attenuation along light beam | ≥ 20 % |
| Connection type | Male connector M12, 4-pin 7) |
| Circuit protection |
A 8) B 9) C 10) D 11) |
| Protection class | III |
| Weight | 240 g |
| Housing material | Stainless steel, Stainless steel V4A (1.4404, 316L) |
| Optics material | Plastic, Plan, PPS (Grilamid) |
| Enclosure rating |
IP67 IP68 IP69K 12) |
| Test input sender off | TE to 0 V |
| Ambient operating temperature | –25 °C … +80 °C 13) |
| Ambient temperature, storage | –40 °C … +80 °C |
| UL File No. | FDA, UL No. NRKH.E181493 & cUL No. NRKH7.E181493 |
- 1) Limit values.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load, at VS 30 V DC.
- 4) Control wire open: dark switching D.ON.
- 5) Signal transit time with resistive load.
- 6) With light/dark ratio 1:1.
- 7) With gold plated contact pins, PPS with FDA certificate.
- 8) A = VS connections reverse-polarity protected.
- 9) B = interference suppression.
- 10) D = outputs overcurrent and short-circuit protected.
- 11) D = inputs and output reverse-polarity protected.
- 12) With correct mounted IP69K connector.
- 13) +100 °C at max 15 minutes.
Safety-related parameters
| MTTFD | 415 years |
| DCavg | 0 % |
Classifications
| eCl@ss 5.0 | 27270901 |
| eCl@ss 5.1.4 | 27270901 |
| eCl@ss 6.0 | 27270901 |
| eCl@ss 6.2 | 27270901 |
| eCl@ss 7.0 | 27270901 |
| eCl@ss 8.0 | 27270901 |
| eCl@ss 8.1 | 27270901 |
| eCl@ss 9.0 | 27270901 |
| eCl@ss 10.0 | 27270901 |
| eCl@ss 11.0 | 27270901 |
| eCl@ss 12.0 | 27270901 |
| ETIM 5.0 | EC002716 |
| ETIM 6.0 | EC002716 |
| ETIM 7.0 | EC002716 |
| ETIM 8.0 | EC002716 |
| UNSPSC 16.0901 | 39121528 |