Cảm biến UM30-214113
Thông số kỹ thuật cảm biến sợi quang Sick UM30-214113
đại lý sick | đại lý UM30-214113 | sick việt nam
nhà phân phối sick | nhà phân phối UM30-214113
Mechanics/electronics
| Supply voltage Vs | DC 9 V … 30 V |
| Power consumption | ≤ 2.4 W |
| Initialization time | |
| Design | Cylindrical |
| Thân material |
Metal (nickel-plated brass, PBT) Ultrasonic transducer: polyurethane foam, glass epoxy resin |
| Kích thước ren | M30 x 1.5 |
| Kiểu kết nối | Male connector, M12, 5-pin |
| Chỉ dẫn | LED display, 2 x LED |
| Weight | 210 g |
| Sending axis | Straight |
| Kích thước (W x H x D) | 47.5 mm x 47.5 mm x 102 mm |
| Enclosure rating | IP65 / IP67 |
| Protection class | III |
- Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
- 15 V … 30 V when using the analog voltage output.
- Without load.
Các thông số liên quan đến an toàn
| MTTFD | 101 years |
| DCavg | 0% |
Performance
| Operating range, limiting range | 350 mm … 3,400 mm, 5,000 mm |
| Target | Natural objects |
| Resolution | ≥ 0.18 mm |
| Repeatability | ± 0.15 % 1) |
| Accuracy | ± 1 % 2)3) |
| Temperature compensation | ✔ |
| Thời gian đáp ứng | 180 ms 4) |
| Output time | 43 ms |
| Ultrasonic frequency (typical) | 120 kHz |
| Detection area (typical) | See diagrams |
| Additional function | Teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default |
- 1) In relation to the current measured value, minimum value ≥ resolution.
- 2) Referring to current measurement value.
- 3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
- 4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
Interfaces
|
|||||||||||||||
| Multifunctional input (MF) | 1 x MF | ||||||||||||||
- 1) For 4 mA … 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.
Ambient data
| Ambient temperature, operation | –25 °C … +70 °C |
| Ambient temperature, storage | –40 °C … +85 °C |