Cảm biến UFS3-37B417
Thông số kỹ thuật cảm biến siêu âm Sick UFS3-37B417
đại lý sick | đại lý UFS3-37B417 | sick việt nam
nhà phân phối sick | nhà phân phối UFS3-37B417
| Nguyên tắc chức năng | Ultrasonic detection principle |
| Kích thước (W x H x D) | 20 mm x 37.4 mm x 70 mm |
| Thân design | Fork shaped |
| Fork width | 2.6 mm |
| Fork depth | 42.5 mm |
| Minimum detectable object (MDO) |
Label size: 2 mm Label gap: 1 mm |
| Label detection | ✔ |
| Điều chỉnh |
Teach-in button (Teach-in, sensitivity, light/dark switching) Cable (Teach-in dynamic) |
| Teach-in mode |
1-point teach-in 2-point teach-in Teach-in dynamic |
- Depends on the label thickness.
| Điện áp nguồn | 10 V DC … 30 V DC |
| Gợn sóng | |
| Current consumption | 50 mA |
| Switching frequency | 1.1 kHz |
| Response time | 440 µs |
| Jitter | 40 µs |
| Switching output | Push-pull: PNP/NPN |
| Switching output (voltage) | Push-pull: PNP/NPN High = UV – |
| Switching mode | Light/dark switching |
| Output current Imax. | 100 mA |
| Initialization time | 100 ms |
| Connection type | Male connector M8, 4-pin |
| Cấp bảo vệ | III |
| Circuit protection |
UV connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression |
| Enclosure rating | IP65 |
| Weight | Approx. 100 g |
| Vật liệu thân |
Metal, Zamak Plastic, Glass fiber reinforced plastic |
| Indication |
LED indicator green: power on LED indicator, yellow: Status switching output Q |
- Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- May not exceed or fall below Uv tolerances.
- Without load.
- With light/dark ratio 1:1.
- Signal transit time with resistive load.
- Output current minimal 0.03 mA.
- Reference voltage DC 50 V.
|
|||||||||||||||
| Cấu trúc dữ liệu xử lý A |
Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 = switching signal QInt1 Bit 3 = switching signal QInt2 Bit 4 = alarm QoR Bit 5 = Teach busy Bit 6 … 15 = measured value |
||||||||||||||
|
|||||||||||||||
| Ambient operating temperature | +5 °C … +55 °C 1) |
| Ambient temperature, storage | –20 °C … +70 °C |
| Shock load | According to EN 60068-2-27 |
| EMC | EN 60947-5-2 2) |
| UL File No. | NRKH.E191603 & NRKH7.E191603 |
- 1) Do not bend below 0 °C.
- 2) The sensor complies with the Radio Safety Requirements (EMC) for the industrial sector (Radio Safety Class A). It may cause radio interference if used in a residential area.
| Smart Task name | Base logics |