Cảm biến OD1-B015H05A15
Thông số kỹ thuật cảm biến khoảng cách Sick OD1-B015H05A15
đại lý sick | đại lý OD1-B015H05A15 | sick việt nam
nhà phân phối sick | nhà phân phối OD1-B015H05A15
Mechanics/electronics
| Supply voltage Vs | DC 12 V (–5 %) … DC 24 V (+10 %) |
| Power consumption | ≤ 1.92 W |
| Warm-up time | ≤ 5 min |
| Thân material | Stainless steel |
| Window material | Plastic (PPSU) |
| Kiểu kết nối | Cable with male connector, M12, 5-pin, 30 cm |
| Chỉ dẫn | 4-digit 7-segment display (plus 4 LEDs for status display) |
| Control elements | 4 buttons |
| Weight | 70 g |
| Kích thước (W x H x D) | 17.8 mm x 44.4 mm x 31 mm |
| Enclosure rating | IP67 |
| Protection class | III |
- Without load, with current output.
Performance
| Measuring range | 10 mm … 20 mm |
| Target | Natural objects |
| Repeatability | 1 µm |
| Linearity | ± 10 µm |
| Response time | ≥ 2 ms |
| Measuring frequency | ≤ 2 kHz |
| Output time | ≥ 0.5 ms |
| Light source | Laser, red visible red light |
| Laser class | 1 (IEC 60825-1:2014, EN 60825-1:201 |
| Typ. light spot size (distance) | 700 µm x 500 µm (15 mm) |
| Additional function | Averaging 1 … 512x, automatic or manual sensitivity adjustment, switching mode: window (Wnd), switching mode: distance to object (DtO), switiching mode: object between sensor and background (ObSB), multifunctional input: laser-off / external teach-in / trigger |
- Averaging function set to: 512.
- Constant ambient conditions.
- Measurement on 90 % remission (ceramic, white).
- With fixed sensitivity adjustment and averaging setting = 1. With automatic sensitivity and measuring rate 500 µs: 2 … 7.5 ms response time/measuring rate 1,000 µs: 4 … 15 ms response time.
- Wavelength: 655 nm, max. output: 390 µW (laser class /
Interfaces
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
- 1) Optional over evaluation unit AOD1.
Ambient data
| Ambient temperature, operation | –10 °C … +50 °C |
| Ambient temperature, storage | –20 °C … +60 °C |
| Min. rel. humidity (not condensing) | 35 % |
| Max. rel. humidity (not condensing) | 95 % |
| Temperature drift | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
| Typ. Ambient light immunity |
Artificial light: ≤ 3,000 lx Sunlight: ≤ 10,000 lx |
| Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
| Shock resistance | 50 G (x, y, z axis 3 times each) |
General notes
| Note on use | The sensor head can be used with evaluation unit AOD1 or stand-alone via RS-485 |
| Note | Not free of paint wetting impairment substances. |