Cảm biến DL100-13HA2112
Thông số kỹ thuật cảm biến khoảng cách Sick DL100-13HA2112
đại lý sick | đại lý DL100-13HA2112 | sick việt nam
nhà phân phối sick | nhà phân phối DL100-13HA2112
Supply voltage Vs | DC 18 V … 30 V, limit values |
Ripple | 5 Vpp |
Initialization time | Typ. 1.5 s |
Thân material | Metal (Aluminum die cast) |
Window material | Plastic (PMMA) |
Kiểu kết nối | Male connector, M12, SPEEDCON™ compatible |
Chỉ dẫn | 6 digit 5 x 7 dot matrix display, LEDs |
Weight | Approx. 800 g (with mounting bracket: approx. 1,600 g) |
Current consumption | At 24 V DC |
Kích thước (W x H x D) | 69.4 mm x 82.5 mm x 100.2 mm |
Modulation frequency | Fix |
Enclosure rating | IP65 |
Protection class | III |
- May not fall short of or exceed VS tolerances.
- After loss of reflector
Measuring range | 0.15 m … 220 m, on “diamond grade” reflective tape |
Target | Reflector |
Resolution | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm |
Repeatability |
2.5 mm, at dead time 10 ms 1.25 mm, at dead time 30 ms |
Accuracy | ± 5 mm |
Response time | 2 ms |
Measurement cycle time | 1 ms |
Output time | 1 ms |
Light source | Laser, red visible red light |
Laser class | 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:201 |
Typ. light spot size (distance) | 5 mm + (2 mm x distance in m) |
Max. movement speed | 10 m/s |
Heating | ✔ |
- Statistical error 1 σ, environmental conditions constant, depending on operating mode.
- From 150 mm … 180 mm measuring range the accuracy can reach ± 4 mm.
- Average service life: 100,000 h at TU = +25 °C.
|
|||||||||||||||||||
|
|||||||||||||||||||
Multifunctional input (MF) | 1 x MF1 3) |
- 1) HIGH = > VS – 3 V / LOW =
- 2) Max. 100 nF/20 mH.
- 3) HIGH > 12 V / LOW
Electromagnetic compatibility (EMC) | EN 61000-6-2, EN 61000-6-4 1) |
Ambient temperature, operation |
–40 °C … +55 °C, operation with heating 2) –40 °C … +75 °C, operation with cooling case |
Ambient temperature, storage | –40 °C … +75 °C |
Effect of air pressure | 0.3 ppm/hPa |
Effect of air temperature | 1 ppm/K |
Temperature drift | Typ. 0.1 mm/K |
Typ. Ambient light immunity | ≤ 100,000 lx |
Mechanical load |
Shock: (EN 600 68-2-27) Sine: (EN 600 68-2-6) Noise: (EN 600 68-2-64) |
- 1) This is a Class A device. This device can cause radio interference in living quarters.
- 2) Temperatures
ECl@ss 5.0 | 27270801 |
ECl@ss 5.1.4 | 27270801 |
ECl@ss 6.0 | 27270801 |
ECl@ss 6.2 | 27270801 |
ECl@ss 7.0 | 27270801 |
ECl@ss 8.0 | 27270801 |
ECl@ss 8.1 | 27270801 |
ECl@ss 9.0 | 27270801 |
ECl@ss 10.0 | 27270801 |
ECl@ss 11.0 | 27270801 |
ETIM 5.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 8.0 | EC001825 |
UNSPSC 16.0901 | 41111613 |