Cảm biến VL18-4P2240V
Thông số kỹ thuật cảm biến quang Sick VL18-4P2240V
đại lý sick | đại lý VL18-4P2240V | sick việt nam
nhà phân phối sick | nhà phân phối VL18-4P2240V
Thông số kỹ thuật chung Sick sensor
Nguyên tắc chức năng | Photoelectric retro-reflective sensor |
Nguyên tắc chức năng detail | Dual lens |
Dimensions (W x H x D) | 18 mm x 18 mm x 83 mm |
Housing design (light emission) | Cylindrical |
Housing length | 83 mm |
Thread diameter (housing) | M18 x 1 |
Optical axis | Axial |
Phạm vi cảm biến max. | 0.035 m … 4.5 m 1) |
Phạm vi cảm biến | 0.035 m … 4 m 1) |
Focus | 3° |
Loại ánh sáng | Visible red light |
Nguồn sáng | LED 2) |
Kích thước điểm sáng (khoảng cách) | Ø 60 mm (1 m) |
Angle of dispersion | 3° |
Độ dài sóng | 660 nm |
Điều chỉnh | Single teach-in button (Phạm vi cảm biến) Manual, via Touch-Teach-in |
Special feature | Detecting transparent objects |
Special applications | Hygienic and washdown zones, Detecting transparent objects |
- 1) Reflector PL80A.
- 2) Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | ± 10 % 2) |
Current consumption | 35 mA 3) |
Switching output | PNP 4) |
Switching mode | Light/dark switching 4) |
Switching mode selector | Selectable via L/D control cable |
Signal voltage PNP HIGH/LOW | Approx. VS – 2.0 V / 0 V |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 1 ms 5) |
Switching frequency | 500 Hz 6) |
Attenuation along light beam | ≥ 20 % |
Connection type | Male connector M12, 4-pin 7) |
Circuit protection |
A 8) B 9) C 10) D 11) |
Protection class | III |
Weight | 120 g |
Housing material | Stainless steel, Stainless steel V4A (1.4404, 316L) |
Optics material | Plastic, Plan, PPS (Grilamid) |
Enclosure rating |
IP67 IP68 IP69K 12) |
Special feature | Detecting transparent objects |
Ambient operating temperature | –25 °C … +80 °C 13) |
Ambient temperature, storage | –40 °C … +80 °C |
UL File No. | FDA, UL No. NRKH.E181493 & cUL No. NRKH7.E181493 |
- 1) Limit values.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load, at VS 30 V DC.
- 4) Control wire open: dark switching D.ON.
- 5) Signal transit time with resistive load.
- 6) With light/dark ratio 1:1.
- 7) With gold plated contact pins, PPS with FDA certificate.
- 8) A = VS connections reverse-polarity protected.
- 9) B = interference suppression.
- 10) D = outputs overcurrent and short-circuit protected.
- 11) D = inputs and output reverse-polarity protected.
- 12) With correct mounted IP69K connector.
- 13) +100 °C at max 15 minutes.
Classifications
eCl@ss 5.0 | 27270902 |
eCl@ss 5.1.4 | 27270902 |
eCl@ss 6.0 | 27270902 |
eCl@ss 6.2 | 27270902 |
eCl@ss 7.0 | 27270902 |
eCl@ss 8.0 | 27270902 |
eCl@ss 8.1 | 27270902 |
eCl@ss 9.0 | 27270902 |
eCl@ss 10.0 | 27270902 |
eCl@ss 11.0 | 27270902 |
eCl@ss 12.0 | 27270902 |
ETIM 5.0 | EC002717 |
ETIM 6.0 | EC002717 |
ETIM 7.0 | EC002717 |
ETIM 8.0 | EC002717 |
UNSPSC 16.0901 | 39121528 |