Cảm biến RTN-M1117
Thông số kỹ thuật cảm biến quang Sick RTN-M1117
đại lý sick | đại lý RTN-M1117 | sick việt nam
nhà phân phối sick | nhà phân phối RTN-M1117
Thông số kỹ thuật chung Sick sensor
| Nguyên tắc chức năng | Photoelectric proximity sensor |
| Nguyên tắc chức năng detail | Background suppression |
| Dimensions (W x H x D) | 20.6 mm x 99.2 mm x 48.9 mm |
| Phạm vi cảm biến max. | 60 mm … 900 mm |
| Phạm vi cảm biến | 60 mm … 900 mm |
| Focus | 7° |
| Loại ánh sáng | Infrared light |
| Nguồn sáng | LED |
| Kích thước điểm sáng (khoảng cách) | Ø 20 mm (500 mm) |
| Angle of dispersion | 7° |
| Điều chỉnh | Potentiometer, 9 turns |
| Special applications | ZoneControl |
- Tuổi thọ trung bình: 100,000 h at TU = +25 °C.
Mechanics/electronics
| Supply voltage | 21.6 V DC … 250 V DC, 96 … 250 V AC @ 60 Hz, 111 … 250 V AC @ 50 Hz 1)2)3) |
| Ripple | pp 4) |
| Current consumption | 10 mA 5) |
| Switching output | FET |
| Switching mode | Light switching |
| Signal voltage NPN HIGH/LOW | Approx. VS / |
| Output current Imax. | ≤ 100 mA |
| Response time | 2 ms |
| Switching frequency | 250 Hz |
| Time functions | On delay |
| Delay time | 0 s … 5 s |
| Connection type | Cable, 4-wire, 2 m 6) |
| Circuit protection |
A 7) C 8) D 9) |
| Protection class | II |
| Weight | 175 g |
| Housing material | Plastic, ABS |
| Enclosure rating | IP67 |
| Shock and vibration resistance | According to IEC 68 |
| Ambient operating temperature | –40 °C … +40 °C |
| Ambient temperature, storage | –40 °C … +75 °C |
| UL File No. | NRKH.E189383 & NRKH7.E189383 |
- 1) Limit values.
- 2) UL requires the Rx-Mxxxx sensor to be installed in a circuit protected by a listed fuse, a listed (DHWZ/7) molded-case circuit breaker, or a supplementary R/C protection device (QVNU2/8) with min. 250 V, max. 2 A rating or equivalent.
- 3) The output load and sensor must use the same power source.
- 4) May not exceed or fall below Uv tolerances.
- 5) Without load and valve deenergized.
- 6) Do not bend below 0 °C.
- 7) A = VS connections reverse-polarity protected.
- 8) C = interference suppression.
- 9) D = outputs overcurrent and short-circuit protected.
Safety-related parameters
| MTTFD | 552 years |
| DCavg | 0 % |
Classifications
| eCl@ss 5.0 | 27270904 |
| eCl@ss 5.1.4 | 27270904 |
| eCl@ss 6.0 | 27270904 |
| eCl@ss 6.2 | 27270904 |
| eCl@ss 7.0 | 27270904 |
| eCl@ss 8.0 | 27270904 |
| eCl@ss 8.1 | 27270904 |
| eCl@ss 9.0 | 27270904 |
| eCl@ss 10.0 | 27270904 |
| eCl@ss 11.0 | 27270904 |
| eCl@ss 12.0 | 27270903 |
| ETIM 5.0 | EC002719 |
| ETIM 6.0 | EC002719 |
| ETIM 7.0 | EC002719 |
| ETIM 8.0 | EC002719 |
| UNSPSC 16.0901 | 39121528 |



