Cảm biến PRO2-P100B25A1
Thông số kỹ thuật cảm biến khoảng cách Sick PRO2-P100B25A1
đại lý sick | đại lý PRO2-P100B25A1 | sick việt nam
nhà phân phối sick | nhà phân phối PRO2-P100B25A1
Supply voltage Vs | DC 12 V (–5 %) … DC 24 V (+10 %) |
Power consumption | ≤ 180 mA |
Warm-up time | ≤ 30 min |
Thân material | Metal (zinc diecast) |
Window material | Plastic (Polycarbonat (PC)) |
Kiểu kết nối | Female connector, HRS, 12-pin (I/O, power supply) |
Chỉ dẫn |
2 LEDs (operational status, Laser on/off) Dot matrix display |
Weight | 300 g |
Kích thước (W x H x D) | 40 mm x 94.5 mm x 60 mm |
Enclosure rating | IP67 |
Protection class | III |
- When using analog voltage output reduced to 18 V DC (–5%) … 24 V DC (+10%).
Measuring range | 75 mm … 125 mm |
Measuring width (at measuring distance) |
17 mm (75 mm) 22 mm (100 mm) 27 mm (125 mm) |
Target | Natural objects |
Repeatability |
25 µm, x-direction 2 µm, z-direction |
Linearity |
X-direction ± 170 µm … ± 270 µm Z-direction ± 50 µm |
Response time | ≥ 5 ms |
Light source | Laser, red visible red light |
Laser class | 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:201 |
Typ. light spot size (distance) | 0.3 mm x 32 mm |
Additional function | Timer (ON-OFF delay, one shot, off), averaging 1 … 1,023, sensitivity (adjustable), Measurement functions (average, peak height, bottom height, width, peak height position, bottom height position, edge position, edge count, tilt, area, length, diameter) |
- Typical value; actual value depends on settings and environmental conditions. For details see field of view.
- Measurement on 90 % remission (ceramic, white), for OD25-x measurement on mirror; averaging set to: 256; constant ambient conditions.
- Measurement on 90 % remission (ceramic, white).
- Constant ambient conditions.
- Typical value, high-res mode.
- Wavelength: 655 nm, max. output: 1 mW.
|
|||||||||
|
|||||||||
|
|||||||||
External input | Selectable from bank, trigger, hold, reset, laser off and offset |
- 1) 24 mA for measuring out of range.
Ambient temperature, operation | –10 °C … +40 °C, Operating temperature at VS = 24 V |
Ambient temperature, storage | –20 °C … +60 °C |
Max. rel. humidity (not condensing) | 85 % |
Temperature drift | ± 0.05 % FS/K (FS = Full Scale = Measuring range of sensor) |
Typ. Ambient light immunity |
Artificial light: ≤ 3,000 lx Sunlight: ≤ 10,000 lx |
Vibration resistance | 10 Hz … 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
Shock resistance | 50 G (x, y, z axis 3 times each) |
eCl@ss 5.0 | 27270801 |
eCl@ss 5.1.4 | 27270801 |
eCl@ss 6.0 | 27270801 |
eCl@ss 6.2 | 27270801 |
eCl@ss 7.0 | 27270801 |
eCl@ss 8.0 | 27270801 |
eCl@ss 8.1 | 27270801 |
eCl@ss 9.0 | 27270801 |
eCl@ss 10.0 | 27270801 |
eCl@ss 11.0 | 27270801 |
eCl@ss 12.0 | 27270916 |
ETIM 5.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 8.0 | EC001825 |
UNSPSC 16.0901 | 41111613 |